Vertical PDU, 3 phase with MCB, RS-485 and IP metering, 16A / 380V, 6xC19 + 36xC13, 3.0 m power cord, IEC 309 plug

Vertical PDU, 3 phase with MCB, RS-485 and IP metering, 16A / 380V, 6xC19 + 36xC13, 3.0 m power cord, IEC 309 plug. Technical characteristics and inquiry information for the LANMASTER catalog.
TWT-PDVMT3-6x36-16A

The three-phase AC distribution unit is used for power distribution in telecommunications cabinets and racks. The unit is equipped with a built-in power cord with an IEC309 plug (16A), six C19 sockets and eighteen mixed C19, C13 socket sets.

The power distribution unit provides total monitoring. Remote metering functions include total current, voltage, total power, total energy.

PDU with metering function allows you to optimize power consumption and ensure the protection of electrical circuits. Alarm thresholds can be set to reduce the risk of system overload.

The unit is equipped with an overvoltage protection device to protect against power surges. The distribution unit is 1.9 meter high and can be mounted vertically in 19" cabinets and racks in designated spaces. The PDU is mounted using two mounting brackets located at the ends of the block. The design of the brackets allows them to be rotated 180° for installation parallel to the front side of the PDU.


Vertical trays of LAN-DC series cabinets have special hinged holes arranged with a certain height step. Installing the PDU into these holes is done using two clips located on the back of the PDU case without the use of a tool. This method is fast and convenient. The PDU has the necessary clips in the package.


Specification
Value
Supply voltage240/380 V
Total load currentno more than 16/32A
Socket types36 - IEC 60320 C13
6 - IEC 60320 C19
Dimensions (WxHxD)90x1900x56 mm

Frequently Asked Questions

What is the TWT-PDVMT3-6x36-16A vertical outlet strip used for?

It is a high-capacity three-phase vertical outlet strip with remote monitoring for installation in 19-inch cabinets and racks, distributing power to equipment with C20 and C14 inlets.

How many outlets does the unit have and of what type?

6 outlets of type C19 and 36 outlets of type C13.

Does the unit have a circuit breaker?

Yes, the unit has a built-in circuit breaker.

The breaker won't switch back on after it trips — what should I do?

After tripping, a circuit breaker can get stuck in a mid-trip position, partway between on and off — this happens not only from an overload but also from jolts during shipping. The unit can look faulty from the outside in this state. To restore it, first push the toggle fully into the off position, then switch it back on.

Can switching on all connected equipment at once trip the breaker?

Yes, switching on several devices at the same time — especially switches and other equipment with high inrush current — can briefly push the combined startup current above the breaker's rating and trip it, even though the running load is normal. It's best to power on connected equipment one device at a time, with a short interval between each, rather than all at once.

What can be monitored through this unit, and over which protocols?

The unit supports monitoring over RS-485 and Ethernet interfaces, allowing total current, voltage, total power and energy to be tracked, with configurable alarm thresholds.

What input connector and power cord does the unit have?

The input plug is a three-phase IEC309, with a built-in 3 m power cord.

Does the unit have surge protection?

Yes, it has a built-in surge protection module.

What current and voltage is the unit rated for?

Three-phase, 16 A, 380 V, 50 Hz.

How is the unit mounted in the cabinet?

The unit is installed vertically in 19-inch cabinets and racks using two corner brackets at the ends (rotatable 180° for parallel mounting to the front panel) or two tool-free rear clips for LAN-DC series vertical cable trays — the clips are included..

Which sensors can be connected to the unit?

Door-open sensors (rectangular and round), a smoke sensor and a water-leak sensor for monitored units — all purchased separately.

Didn’t find an answer to your question?

Package dimensions and weight

Single item

Unit length × width × height (mm) Weight (kg) Volume (m3)
pcs 2190 × 210 × 100 8.56 0.04599

Product Codes (1)

  • Vertical PDU, 3 phase with MCB, RS-485 and IP metering, 16A / 380V, 6xC19 + 36xC13, 3.0 m power cord, IEC 309 plug
Specifications are subject to change without notice. For the most current information, consult LANMASTER or an authorized LANMASTER partner/distributor.