TWT, U/UTP, Category 5e, twisted-pair cable, 10-pair, unshielded, PVC, 305 m

TWT, U/UTP, Category 5e, twisted-pair cable, 10-pair, unshielded, PVC, 305 m for copper structured cabling systems. LANMASTER product information, specifications and part number details.
TWT-5EUTP10

Cable comprises 10 pairs of solid copper conductors.

Cable is unshielded (UTP) and compliance with category 5e.

Each conductor is covered with HDPE (high density polyethylene) insulation.

Two conductors are twisted with specially selected step in a single twisted pair. All twisted pairs are grouped in a single bundle with polyethylene tape and enclosed in a PVC jacket.

There is a ripcord under the cable jacket for termination process convenience.

The cable is delivered on reels by 305 meters length. Other construction lengths are available by order.

Specification Value
Jacket Color Blue
Jacket Material PVC
Insulation Material HDPE (high density polyethylene)
Conductor Type Solid
Conductor Gauge 24 AWG
Nominal Velocity Propagation (NVP) 66%
Cable Diameter 7.8 mm
Cable Length per Reel 305 m
Operating Temperature -20 ºC to 75 ºC
Regulatory Certifications UL VERIFIED
Regulatory Compliance TIA/EIA 568.2-D cat. 5; ISO/IEC 11801
Color Coding
Pair Color Pair Color
1 white - blue 6 red - blue
2 white - orange 7 red - orange
3 white - green 8 red - green
4 white - brown 9 red - brown
5 white - grey 10 red - grey

Most frequently asked questions and answers

What is the TWT-5EUTP10 cable used for?

TWT-5EUTP10 is a unshielded category 5e cable made of 10 pairs of solid copper conductors. The multi-pair cable is used for backbone links between cross-connects and floor cabinets, telephone and low-voltage backbones and for connecting telephone exchange ports to cross-connect equipment. For connecting a work area over Ethernet use a four-pair cable. The conductor size is 24 AWG.

TWT, U/UTP, Category 5e, twisted-pair cable, 10-pair, unshielded, PVC, 305 m TWT-5EUTP10
Appearance TWT-5EUTP10
What is the TWT-5EUTP10 cable made of and what are its features?

Each conductor is insulated with high-density polyethylene (HDPE); two conductors are twisted into a pair, and all pairs are enclosed in a common sheath. The cable has a PVC (polyvinyl chloride) sheath. The construction also includes: a ripcord for stripping the sheath. The operating temperature range of the cable is up to +75 °C.

How do I terminate the TWT-5EUTP10 cable in an outlet or patch panel?

Strip the outer sheath over the minimum length without damaging the conductor insulation. Untwist the pairs only as far as needed for termination and arrange the conductors according to the colour scheme on the module or panel (T568B or T568A, identical along the whole link). Punch the conductors down with a punch-down tool for 110 or Krone contacts and trim the excess. Do not terminate with a screwdriver: it damages the contacts and the insulation.

How do I identify the pair numbers in the TWT-5EUTP10 multi-pair cable?

Pairs are numbered according to the standard colour code: the primary colour defines a group of five pairs (white, red, black, yellow, violet) and the secondary colour defines the pair within the group (blue, orange, green, brown, slate). For example, pair 1 is white/blue, pair 6 is red/blue, pair 13 is black/green. Ring out and label the pairs before termination.

How do I terminate the TWT-5EUTP10 multi-pair cable on a cross-connect or patch panel?

Strip the sheath to the required length, separate the bundles and pairs by the colour code and route them to 110-type blocks or Krone/LSA strips in numbering order. For a high-count cable, fix it to a bracket or with a clamp so that its weight is not transferred to the contacts. Punch down the pairs while keeping the twist up to the termination point and label the blocks. For switching telephone lines, use a telephone patch panel with a multi-pair input.

Can the TWT-5EUTP10 multi-pair cable be used for Ethernet?

To connect work areas and network equipment over Ethernet, use a four-pair cable of the appropriate category. The multi-pair cable is intended for backbone and telephone links, where one pair serves one channel. If data is nevertheless transmitted over it, use different bundles for different systems and check the link with a tester.

How do I install the TWT-5EUTP10 cable correctly?

Unwind the cable without loops or kinks and do not exceed the permitted pulling force. Observe the minimum bend radius and do not tighten cable ties so that the sheath is crushed. Do not run the cable close to and in parallel with power lines; cross them at an angle close to 90°. Leave a service loop at the outlet and in the cabinet.

How do I unwind the TWT-5EUTP10 cable from its package and how do I store it?

Place the reel on a rotating support and unwind the cable by turning the reel instead of pulling the turns off the side. Store the cable in a dry room in its factory packaging and protect the cable ends from moisture and contamination.

Didn’t find an answer to your question?

Package dimensions and weight

Single item

Unit length × width × height (mm) Weight (kg) Volume (m3)
reel 330 × 330 × 270 37 0.029403

Product Codes (1)

  • TWT, U/UTP, Category 5e, twisted-pair cable, 10-pair, unshielded, PVC, 305 m
Specifications are subject to change without notice. For the most current information, consult LANMASTER or an authorized LANMASTER partner/distributor.