TWT, U/UTP, Category 5e, twisted-pair cable, 1-pair, unshielded, PVC, gray, 305 m
Single pair cables are budget solution for voice, fair alarm, and security cabling. Also, they can be used as cross wires.
The cable comprises two solid copper 24 AWG conductors. Each conductor is insulated with HDPE (high density polyethylene). Those two conductors are twisted with specially selected step in a single twisted pair and covered with PVC jacket.
| Specification | Value |
| Jacket Color | Grey |
| Jacket Material | PVC (polyvinyl chloride) |
| Insulation Material | HDPE (high density polyethylene) |
| Conductor Gauge, single | 24 AWG |
| Conductor Type | Solid |
| Cable Diameter | 3 mm |
| Operating Temperature | -20 ºC to +75 ºC |
| Cable Length per Box | 305 m |
| Regulatory Certifications | ETL VERIFIED, UL, CSA |
| Regulatory Compliance | TIA/EIA 568-D.2 cat. 5e |
Most frequently asked questions and answers
What is the TWT-5EUTP1-GY cable used for?
What is the TWT-5EUTP1-GY cable made of and what are its features?
Each conductor is insulated with high-density polyethylene (HDPE); two conductors are twisted into a pair, and all pairs are enclosed in a common sheath. The cable has a PVC (polyvinyl chloride) sheath.
How do I terminate the TWT-5EUTP1-GY cable in an outlet or patch panel?
Strip the outer sheath over the minimum length without damaging the conductor insulation. Untwist the pairs only as far as needed for termination and arrange the conductors according to the colour scheme on the module or panel (T568B or T568A, identical along the whole link). Punch the conductors down with a punch-down tool for 110 or Krone contacts and trim the excess. Do not terminate with a screwdriver: it damages the contacts and the insulation.
How do I install the TWT-5EUTP1-GY cable correctly?
Unwind the cable without loops or kinks and do not exceed the permitted pulling force. Observe the minimum bend radius and do not tighten cable ties so that the sheath is crushed. Do not run the cable close to and in parallel with power lines; cross them at an angle close to 90°. Leave a service loop at the outlet and in the cabinet.
How do I unwind the TWT-5EUTP1-GY cable from its package and how do I store it?
Pull the cable from the centre of the box without forming loops or figure-eights and hold the box in place. Store the cable in a dry room in its factory packaging and protect the cable ends from moisture and contamination.
Package dimensions and weight
Single item
| Unit | length × width × height (mm) | Weight (kg) | Volume (m3) |
|---|---|---|---|
| box | 300 × 300 × 210 | 5 | 0.0189 |