Fiber Optic Cleaning Tools for 1.25 mm Based Connectors

Fiber Optic Cleaning Tools for 1.25 mm Based Connectors LAN-FT-CL/OK1: specifications, description and use in structured cabling and LANMASTER infrastructure projects.
LAN-FT-CL/OK1

The tool is designed to clean fiber MU/LC adapters with a ferrule diameter of 1.25 mm, or the end faces of optical connectors without removing them from the adapter. Avoids the time-consuming procedure of dismantling adapters for cleaning the connectors installed in them.

The tool cartridge is designed for 800 cleaning cycles. The tool is equipped with a readiness indicator. White indicator - tool is ready to use. Completely red indicator - the cartridge is empty and needs to be replaced.

The tool has two operating modes. Standard cleaning and advanced (thorough) cleaning.

Select the operating mode by moving the mode switcher to the desired position.

The cleaning process is carried out in one pass of the rod.

Supplied in an individual package, also includes user's manual in English.

Key Features:

  • Ease of use.
  • High-quality, alcohol-free cleaning with special cleaning tape.
  • Has antistatic properties.
  • More than 750 cleaning cycles with one cartridge.
  • Cleaning the connectors inserted in the adapters.
  • Cleaning of patch cords with a ferrule diameter of 1.25 mm.
  • Cleaning connectors with PC and APC polish types.

Frequently Asked Questions

What is the LAN-FT-CL/OK1 designed for?

The LAN-FT-CL/OK1 is a dry cleaner for optical connector end faces with a 1.25 mm ferrule. It can clean a connector installed in an adapter and a patch-cord connector.

What does the 1.25 mm size refer to?

It is the diameter of the connector ferrule whose end face the tool cleans; it is not the optical fiber diameter. Check the connector size and construction against the cleaner’s compatibility before use.

Will the OK1 fit every connector with a 1.25 mm ferrule?

Matching diameters alone may not establish compatibility if the connector design or access to the end face differs. Check the specific connector type against the cleaner’s compatibility and never force the tip into place.

Can I clean a connector without removing it from the adapter?

Yes. The LAN-FT-CL/OK1 is designed to clean a connector end face directly in an adapter. Clear the relevant port before cleaning and follow the cleaner manufacturer’s instructions.

Cleaning a connector in an adapter with the LAN-FT-CL/OK1
Cleaning a connector installed in an adapter
Can I clean an optical patch-cord connector?

Yes, if the patch-cord ferrule is 1.25 mm and its construction is compatible with the cleaner. Remove the dust cap before cleaning and do not touch the end face.

Cleaning an optical patch-cord connector with the LAN-FT-CL/OK1
Cleaning an optical patch-cord connector
Is the cleaner suitable for PC and APC polish types?

The LANMASTER catalogue lists connectors with PC and APC polish for this cleaner. Check the connector against the cleaner’s compatibility; cleaning does not change the polish type.

Should I clean a connector before every mating?

Inspect the end face before every connection. Clean it when inspection shows contamination rather than simply because it is being reconnected: unnecessary handling and cleaning can also introduce contamination.

How do I check whether cleaning worked?

Inspect the end face after cleaning with a suitable fiber-optic inspection microscope. If contamination remains, repeat the procedure according to the cleaner instructions and inspect again before mating.

How should I use the cleaner without damaging the connector?

Align the cleaner guide with the connector and insert it straight, without tilting or excessive force. Perform the cleaner’s intended operating stroke, withdraw it and inspect the end face. Follow the LAN-FT-CL/OK1 instructions for the detailed sequence.

Operating stroke of the LAN-FT-CL/OK1 during connector cleaning
Perform the cleaning cycle with the intended operating stroke
Do I need to add alcohol or another liquid?

No. The LAN-FT-CL/OK1 uses a special cleaning tape, and LANMASTER describes cleaning without alcohol. Do not apply liquid to the end face, port or tape unless the cleaner instructions specifically require it.

Can the OK1 clean the adapter sleeve itself?

No. The cleaner cleans the connector end face, including one installed in an adapter. It is not designed to clean the adapter’s internal sleeve or port housing.

Can I clean both sides of a duplex connection in one action?

Inspect and clean each connector end face separately, using the matching guide and the manufacturer’s procedure. Inspect every end face that will be mated.

How many cleaning cycles is one cartridge rated for?

The LANMASTER catalogue specifies more than 750 cleaning cycles per cartridge. This is the stated consumable life; it does not confirm that every end face will be clean after a single use.

Can I use the OK1 on connectors with 2.5 mm ferrules?

Use the matching LAN-FT-CL/OK2 cleaner for 2.5 mm ferrules. Do not try to compensate for a size mismatch by applying force.

Does the cleaner remove contamination from the ferrule sides or inside the port?

The cleaner is designed to clean the connector end face. Do not assume the port is clean just because the end face was treated; use a compatible procedure and tool if other surfaces or the adapter itself need cleaning.

Can I clean a connector while it is connected to active equipment?

Do not disconnect or clean an optical connection without following the site procedure for isolating the line. Treat an open optical port as potentially active and never look into the end of a fiber or connector.

What should I do if the connector still appears contaminated after cleaning?

Inspect it again and repeat the cleaning only as directed by the cleaner instructions. Do not increase pressure or wipe the end face with improvised materials. If contamination or damage remains, stop using the connector and examine it with suitable equipment.

What should I check if loss does not improve after cleaning?

Check both mating connector end faces, adapter cleanliness, seating and connector compatibility. Then measure the link with suitable equipment using the accepted method: contamination is only one possible cause of high loss.

How does LAN-FT-CL/OK1 differ from LAN-FT-CL/OK2?

OK1 is sized for 1.25 mm ferrules — LC and MU connectors. OK2 is sized for 2.5 mm ferrules — SC, FC and ST. Select the cleaner by ferrule diameter, not by connector type.

Didn’t find an answer to your question?

Package dimensions and weight

Single item

Unit length × width × height (mm) Weight (kg) Volume (m3)
pcs 190 × 30 × 30 0.02 0.000171

Package

Unit length × width × height (mm) Weight (kg) Volume (m3)
box 135 × 190 × 30 0.2 0.00077
pcs 190 × 25 × 25 0.033 0.000119

Product Codes (1)

  • Fiber Optic Cleaning Tools for 1.25 mm Based Connectors
Specifications are subject to change without notice. For the most current information, consult LANMASTER or an authorized LANMASTER partner/distributor.