TWT optical patch cord, PVC, SC/UPC-FC/UPC, SM

TWT optical patch cord, PVC, SC/UPC-FC/UPC, SM TWT-SC-FC-SM: specifications, description, purpose and use in structured cabling, data center and LANMASTER infrastructure projects.
TWT-SC-FC-SM

The patch cord is a piece of optical cable 9/125 with optical FC connector at one end and SC at another end.

TWT patch cords are produced in a PVC (polyvinylchloride) jacket and with a standard polishing quality.

The patch cord is used for connection between various network devices or between a network device and a fiber optic cross or inside a fiber optic cross.

Installed connectors are numbered.

Each patch cord comes individually packaged.

Specifications

Insertion loss
Return loss
Number of fibers (cord type)1, 2 fiber (simplex, duplex)
Fiber optic type9/125 (OS2)
Buffer coatingPolyvinylchloride (PVC)
JacketPolyvinylchloride (PVC)
Connector typeFC, 2FC (duplex), SC, 2SC (duplex)
Polish style
PC, UPC, APC
Buffer coating thickness3 mm

Patch cords with a length of 1, 2, 3 and 5 meters are constantly in stock. Patch cords of other lengths are also available on request as simplex or duplex structure with various polishing options (PC, UPC, APC).


Frequently Asked Questions

What is the TWT-SC-FC-SM patch cord used for?

TWT-SC-FC-SM is a TWT optical patch cord (SC/PC-FC/PC) on single-mode 9/125 µm (OS2) fiber, with SC (Subscriber Connector) connectors at one end and FC (Ferrule Connector) connectors at the other. It connects active network equipment together, connects equipment to an optical distribution frame and is used for patching inside the frame. The jacket is polyvinyl chloride (PVC) and the cable buffer is 3 mm. The installed connectors are numbered and each patch cord is supplied in individual packaging.

TWT-SC-FC-SM product
TWT-SC-FC-SM product
Which versions are in the series and how do I choose the length?

The series includes: simplex (SU): 0.5, 1.0, 2.0, 3.0, 5.0 m; duplex (SU): 0.5, 1.0, 2.0, 3.0, 5.0 m. A simplex patch cord has one fiber, a duplex one has two (transmit and receive). For an equipment-to-equipment link with two fibers choose the duplex version. Choose the length with a margin for routing through organizers and reaching the ports, without tension. Other lengths are available to order.

Can a single-mode patch cord be used with multimode equipment, or the other way round?

No. Use a single-mode patch cord (9/125 µm fiber) with single-mode modules and links, and a multimode one (50/125 µm) only with multimode. Mixing fiber types sharply increases loss and the link may not work. Check the fiber type by the patch cord marking and the equipment documentation, not by the jacket color.

Can connectors with different polish — PC, UPC (Ultra Physical Contact) and APC (Angled Physical Contact) — be mated?

PC and UPC (Ultra Physical Contact) connectors can be mated with each other. APC (Angled Physical Contact) connectors (8° angled end face, usually green) mate only with APC. Mating APC with PC or UPC causes high loss and can damage the end faces. Choose the polish according to the project and equipment: the polish of this patch cord is given in its name — SC/PC-FC/PC.

When is a patch cord with different SC (Subscriber Connector) and FC (Ferrule Connector) connectors needed?

This patch cord connects devices with different types of optical ports or adapters, for example equipment with an SC (Subscriber Connector) port and a patch panel with FC (Ferrule Connector) adapters. It avoids adapters and extra mated pairs that add loss. The connector type at each end must match the port it plugs into.

How do I keep the polarity of a duplex patch cord correct?

In a duplex link the transmitter (Tx) of one device must connect to the receiver (Rx) of the other. The connectors of the patch cord are numbered — keep the same layout at both ends of the link. If the link does not come up, swap the two connectors at one end of the patch cord or use a patch cord with reverse polarity.

How do I clean the connectors before connecting?

Inspect the connector end faces before each connection and clean them if dirty: dust and fingerprints on the end face are a common cause of loss. Suitable tools: for FC/SC connectors (2.5 mm ferrule) — LAN-FT-CL/OK2. Keep unused connectors closed with protective caps.

Where can a PVC-jacketed patch cord be used?

A polyvinyl chloride (PVC) jacket suits patching in ordinary rooms — offices, telecom cabinets and distribution frames. For rooms with higher fire-safety requirements and in data centers choose patch cords with an LSZH (low-smoke zero-halogen) jacket, for example the LANMASTER series.

How should I route and store the patch cord?

Do not kink or twist the patch cord and do not overtighten cable ties: loss increases at a small bend radius. Connect and disconnect the patch cord by the connector body, not by the cable. Store it in its individual packaging with protective caps on the connectors.

Didn’t find an answer to your question?

Package dimensions and weight

Single item

Product code Unit length × width × height (mm) Weight (kg) Volume (m3)
TWT-SC-FC/SU-0.5 pcs 150 × 10 × 150 0.021 0.000225
TWT-2SC-2FC/SU-0.5 pcs 150 × 5 × 150 0.037 0.000113

Product Codes (10)

  • TWT optical patch cord, PVC, simplex, SC/UPC-FC/UPC, SM OS2, 0.5 m
  • TWT optical patch cord, PVC, simplex, SC/UPC-FC/UPC, SM OS2, 1.0 m
  • TWT optical patch cord, PVC, simplex, SC/UPC-FC/UPC, SM OS2, 2.0 m
  • TWT optical patch cord, PVC, simplex, SC/UPC-FC/UPC, SM OS2, 3.0 m
  • TWT optical patch cord, PVC, simplex, SC/UPC-FC/UPC, SM OS2, 5.0 m
  • TWT optical patch cord, PVC, duplex, SC/UPC-FC/UPC, SM OS2, 0.5 m
  • TWT optical patch cord, PVC, duplex, SC/UPC-FC/UPC, SM OS2, 1.0 m
  • TWT optical patch cord, PVC, duplex, SC/UPC-FC/UPC, SM OS2, 2.0 m
  • TWT optical patch cord, PVC, duplex, SC/UPC-FC/UPC, SM OS2, 3.0 m
  • TWT optical patch cord, PVC, duplex, SC/UPC-FC/UPC, SM OS2, 5.0 m
Specifications are subject to change without notice. For the most current information, consult LANMASTER or an authorized LANMASTER partner/distributor.