TWT, coupler

TWT, coupler for copper structured cabling systems. LANMASTER product information, specifications and part number details.
TWT-CN110xTP5yy

The connection box is designed to connect two lines of unshielded 4-pair cable by termination on IDC wiring blocks.

It is used during repair work to quickly restore the connection of a damaged cable, as well as to organize a transition point.

Dimensions (DxWxH) - 34x61,5x23,5 mm.

Most frequently asked questions and answers

What is the TWT-CN110xTP5yy connection module used for?

The connection module is intended for joining two sections of unshielded 4-pair cable by termination on IDC (insulation displacement contact) connectors (insulation displacement contacts). It complies with the requirements of category 5e. It is used in repair work for quick restoration of a damaged cable connection and for building a consolidation point (an intermediate cable connection point).

TWT, coupler TWT-CN110xTP5yy
Appearance TWT-CN110xTP5yy
How do I join cables in the TWT-CN110xTP5yy module?

Strip the cable sheaths over the required length, arrange the conductors according to the colour marking of the module and punch them down to the IDC (insulation displacement contact) contacts with a punch-down tool. Use one wiring scheme (T568A or T568B) for both sections and keep the pairs twisted up to the termination point. The module can be fixed on a wall, a ceiling or another surface, or left inside a cable bundle.

Does the TWT-CN110xTP5yy connection module affect link performance?

Any additional connection adds loss, so use the module sparingly — for repairs and consolidation points. The link category is determined by its weakest component, so the cables must comply with the module category or be higher.

What should I do if the link with the module TWT-CN110xTP5yy does not work or works unstably?

Check that the conductors are connected by the same scheme at both ends of the link, that there is no open or short circuit and that all connectors are intact and fully latched. Check the link with a tester and make sure the category of all components is not lower than required.

What should I do if the product TWT-CN110xTP5yy does not work or works unstably?

Check that the connectors are fully latched, the conductors are connected by the same scheme at both ends of the link and there is no open or short circuit. Check the link with a tester, redo the termination if necessary and make sure the category of all components is not lower than required.

Didn’t find an answer to your question?

Package dimensions and weight

Single item

Product code Unit length × width × height (mm) Weight (kg) Volume (m3)
TWT-CN110UTP5E pcs 65 × 25 × 30 0.025 0.000049
TWT-CN110STP5E pcs 60 × 30 × 25 0.02 0.000045
TWT-CN110UTP6 pcs 65 × 25 × 30 0.025 0.000049
TWT-CN110STP6 pcs 60 × 30 × 25 0.015 0.000045

Package

Product code Unit length × width × height (mm) Weight (kg) Volume (m3)
TWT-CN110UTP5E box 505 × 365 × 285 10.71 0.052533
TWT-CN110UTP5E box 330 × 240 × 120 1.26 0.009504
TWT-CN110UTP6 box 510 × 365 × 270 13.48 0.050261
TWT-CN110UTP6 box 340 × 230 × 120 1.26 0.009384

Product Codes (4)

Specifications are subject to change without notice. For the most current information, consult LANMASTER or an authorized LANMASTER partner/distributor.