LANMASTER, coupler, shielded, unshielded
The field terminated connector box is designed to connect two lines of unshielded twisted pair cable in the field. Conventional side cutters are sufficient to install the connector box.
It is used during repair work to quickly restore the connection of a damaged cable, as well as to organize a consolidation point. Due to its low weight and dimensions, it can remain unsecured, or fit inside the cable harness.
For ease of installation, the inserts contain a wiring diagram for the cable conductors, in accordance with the T568A and T568B.
The cable is securely fixed with the connector box cover after termination.
| Category | 6 |
| Conductor diameter | 24–22 AWG |
| EMI protection | Unshielded |
| Terminated conductors | Copper solid conductors |
| Outer diameter of terminated cable | 5–8 mm |
Frequently asked questions and answers
What is the LAN-TMC-U6 designed for?
Which cables are compatible with LAN-TMC-U6?
The coupler is designed for unshielded Category 6 cable with 24–22 AWG solid copper conductors and an overall cable diameter of 5–8 mm. Check the cable parameters against the product specifications before installation.
How does LAN-TMC-U6 differ from the shielded LAN-TMC-S6?
LAN-TMC-U6 is the unshielded version with no contact to the cable shield, rated for a 5–8 mm diameter. LAN-TMC-S6 is the shielded version for 5–9.5 mm cable with an additional shield-clamping feature. Choose the model that matches the cable type in use.
Can it be used to join shielded cable?
LAN-TMC-U6 is the unshielded version and does not provide contact with the cable shield. For a shielded link, use LAN-TMC-S6 to maintain shield continuity.
Which tools are needed for installation?
Ordinary side cutters are sufficient for trimming the tailpieces and conductors. Carefully remove the cable jacket with a suitable stripper without damaging the pair insulation.
Is a special crimping tool required?
No. The contact inserts use tool-less termination: place the insert in the body and press it until it locks; the contacts pierce the conductor insulation.
How much of the outer cable jacket should be removed?
Remove approximately 3–4 cm of the outer jacket without nicking the insulation of the twisted pairs. Then separate the pairs as shown in the assembly instructions.
What should be done with the cable separator?
If the cable contains a cross-shaped separator or ripcord, trim it close to the jacket. Do not damage the insulation of the individual pairs.
Should the conductors be arranged using T568A or T568B?
Use the scheme specified for the link and follow the markings on the contact insert. Keep the same wiring scheme at both ends of the joined link.
Do I need to strip the insulation from each conductor?
No. The insert contacts pierce the conductor insulation when installed. Seat each conductor fully in its channel and do not strip it separately.
How should the tailpiece be trimmed to fit the cable?
Before termination, match the tailpiece to the cable diameter and carefully trim its stepped end at the appropriate mark using side cutters. Prepare both tailpieces and feed the cables through them in advance.
How are the cables secured after termination?
Press both contact inserts into the body until they lock. Slide the tailpieces fully into place; the cable is held by the termination and the tailpiece seated on the body.
Does the coupler need to be fixed to a wall or tray?
Its low weight and compact size allow it to remain unsecured or be placed within a cable bundle. Still protect the joint from tension, impact, and sharp bends, and follow the project and site requirements.
Can LAN-TMC-U6 be used as a consolidation point?
Yes. This is a supported application for the product. Choose an accessible location for maintenance and protect the connection from mechanical loads.
What should be checked after installation?
Confirm that both contact inserts and tailpieces are fully locked, the cables cannot rotate, and the pairs are not sharply bent. Test the wiring with a suitable cable tester as required by the project.
Can the coupler be reused after disassembly?
The contacts pierce conductor insulation on first installation, so re-terminating the same conductors weakens the connection. For a new termination, use a new coupler and an undamaged section of cable.
How many LAN-TMC-U6 couplers are needed for a link with several damaged spots?
One coupler per break or repair point. If there are multiple damaged spots, factor in the cumulative signal degradation and replace the damaged section entirely where possible.
Package dimensions and weight
Single item
| Product code | Unit | length × width × height (mm) | Weight (kg) | Volume (m3) |
|---|---|---|---|---|
| LAN-TMC-U6 | pcs | 50 × 50 × 10 | 0.015 | 0.000025 |