LANMASTER, Category 6A, coupler, shielded
LANMASTER, Category 6A, coupler, shielded. Product for LANMASTER copper structured cabling systems. Use in couplers applications according to the project design and product specifications.
Most frequently asked questions and answers
What is the LAN-CNB-STP6A connection module used for?
The connection module is intended for joining two sections of shielded 4-pair cable by termination on IDC (insulation displacement contact) connectors (insulation displacement contacts). It complies with the requirements of category 6A. It is used in repair work for quick restoration of a damaged cable connection and for building a consolidation point (an intermediate cable connection point).
How do I join cables in the LAN-CNB-STP6A module?
Strip the cable sheaths over the required length, arrange the conductors according to the colour marking of the module and punch them down to the IDC (insulation displacement contact) contacts with a punch-down tool. Use one wiring scheme (T568A or T568B) for both sections and keep the pairs twisted up to the termination point. Connect the screens of both cables through the shielding body of the module. The module can be fixed on a wall, a ceiling or another surface, or left inside a cable bundle.
Does the LAN-CNB-STP6A connection module affect link performance?
Any additional connection adds loss, so use the module sparingly — for repairs and consolidation points. The link category is determined by its weakest component, so the cables must comply with the module category or be higher.
What should I do if the link with the module LAN-CNB-STP6A does not work or works unstably?
Check that the conductors are connected by the same scheme at both ends of the link, that there is no open or short circuit and that all connectors are intact and fully latched. Check the link with a tester and make sure the category of all components is not lower than required.
What should I do if the product LAN-CNB-STP6A does not work or works unstably?
Check that the connectors are fully latched, the conductors are connected by the same scheme at both ends of the link and there is no open or short circuit. Check the link with a tester, redo the termination if necessary and make sure the category of all components is not lower than required.