LANMASTER, coupler, shielded

LANMASTER, coupler, shielded for copper structured cabling systems. LANMASTER product information, specifications and part number details.
LAN-CNB-STP6

LANMASTER, coupler, shielded. Product for LANMASTER copper structured cabling systems. Use in couplers applications according to the project design and product specifications.

Most frequently asked questions and answers

What is the LAN-CNB-STP6 connection module used for?

The connection module is intended for joining two sections of shielded 4-pair cable by termination on IDC (insulation displacement contact) connectors (insulation displacement contacts). It complies with the requirements of category 6. It is used in repair work for quick restoration of a damaged cable connection and for building a consolidation point (an intermediate cable connection point).

LANMASTER, coupler, shielded LAN-CNB-STP6
Appearance LAN-CNB-STP6
How do I join cables in the LAN-CNB-STP6 module?

Strip the cable sheaths over the required length, arrange the conductors according to the colour marking of the module and punch them down to the IDC (insulation displacement contact) contacts with a punch-down tool. Use one wiring scheme (T568A or T568B) for both sections and keep the pairs twisted up to the termination point. Connect the screens of both cables through the shielding body of the module. The module can be fixed on a wall, a ceiling or another surface, or left inside a cable bundle.

Does the LAN-CNB-STP6 connection module affect link performance?

Any additional connection adds loss, so use the module sparingly — for repairs and consolidation points. The link category is determined by its weakest component, so the cables must comply with the module category or be higher.

What should I do if the link with the module LAN-CNB-STP6 does not work or works unstably?

Check that the conductors are connected by the same scheme at both ends of the link, that there is no open or short circuit and that all connectors are intact and fully latched. Check the link with a tester and make sure the category of all components is not lower than required.

What should I do if the product LAN-CNB-STP6 does not work or works unstably?

Check that the connectors are fully latched, the conductors are connected by the same scheme at both ends of the link and there is no open or short circuit. Check the link with a tester, redo the termination if necessary and make sure the category of all components is not lower than required.

Didn’t find an answer to your question?

Package dimensions and weight

Single item

Product code Unit length × width × height (mm) Weight (kg) Volume (m3)
LAN-CNB-STP6 pcs 65 × 35 × 25 0.067 0.000057

Package

Product code Unit length × width × height (mm) Weight (kg) Volume (m3)
LAN-CNB-STP6 box 390 × 255 × 130 6.92 0.012929
LAN-CNB-STP6 pack 350 × 230 × 60 3.27 0.00483

Product Codes (1)

Specifications are subject to change without notice. For the most current information, consult LANMASTER or an authorized LANMASTER partner/distributor.