LANMASTER, F/UTP, Category 6, RJ45 patch cord, 4-pair, LSZH, 305 m

LANMASTER, F/UTP, Category 6, RJ45 patch cord, 4-pair, LSZH, 305 m for copper structured cabling systems. LANMASTER product information, specifications and part number details.
LAN-6EFTP-PT-LSZH-хх

LANMASTER, F/UTP, Category 6, RJ45 patch cord, 4-pair, LSZH, 305 m. Product for LANMASTER copper structured cabling systems. Use in lanmaster cables applications according to the project design and product specifications.

Most frequently asked questions and answers

What is the LAN-6EFTP-PT-LSZH-хх cable used for?

LAN-6EFTP-PT-LSZH-хх is a screened (overall foil screen) category 6 cable made of 4 pairs of stranded copper conductors. The cable is intended for making flexible patch cords and for connections that are bent and reconnected frequently. The conductor size is 24 AWG.

LANMASTER, F/UTP, Category 6, RJ45 patch cord, 4-pair, LSZH, 305 m LAN-6EFTP-PT-LSZH-хх
Appearance LAN-6EFTP-PT-LSZH-хх
What is the LAN-6EFTP-PT-LSZH-хх cable made of and what are its features?

Each conductor is insulated with high-density polyethylene (HDPE); two conductors are twisted into a pair, and all pairs are enclosed in a common sheath. The cable has a low-smoke zero-halogen (LSZH) sheath. The construction also includes: a drain wire.

Which network and link length does the LAN-6EFTP-PT-LSZH-хх cable support?

Category 6 is rated up to 250 MHz and Gigabit Ethernet; 10GBASE-T is possible only over a limited link length (up to 55 m in the standards, provided the conditions are met). For links up to 100 m, the ISO/IEC 11801 and TIA-568 standards allow a permanent link of up to 90 m plus patch cords totalling up to 10 m. Do not exceed these values, otherwise the link may run at a reduced speed or with errors.

Which cable category should I choose: 5e, 6 or 6A?

Category 5e or 6 is enough for Gigabit Ethernet at work areas. Choose category 6A if 10 Gbit/s (10GBASE-T) is required over the whole link length, and category 6 if you need extra headroom in frequency performance. All components of the link (cable, outlets, patch panels, patch cords) must be of the same or a higher category: the link performance is determined by its weakest element.

How do I ground the screen of the LAN-6EFTP-PT-LSZH-хх cable?

Connect the cable screen to ground through shielded outlets and a grounded patch panel; in the telecommunications cabinet bond the panel to the earthing bar. Use shielded components along the whole link: cable, modules, patch panels and patch cords. Do not leave the screen ungrounded and do not connect it to earthing points with a potential difference between them: current will flow through the screen and it will become a source of noise instead of protection. Follow the building grounding design.

When do I need a cable with a low-smoke zero-halogen (LSZH) sheath?

An LSZH (low smoke zero halogen) sheath emits little smoke and no halogens when burning, so such a cable is chosen for premises with many people, cable ducts, escape routes, data centres and other places where the design or fire-safety regulations require it. If the design has no such requirements, a PVC-sheathed cable can be used.

Can the LAN-6EFTP-PT-LSZH-хх cable be used for Power over Ethernet (PoE)?

The cable conductors are copper, so the link is suitable for Power over Ethernet (PoE). At PoE++ power levels, cables heat up in dense bundles, so in such cases choose a cable of a higher category with larger conductors and avoid very tight bundles.

How do I terminate the LAN-6EFTP-PT-LSZH-хх cable with RJ-45 connectors?

For stranded conductors use RJ-45 connectors designed for stranded cable: their contact blades are intended for thin conductors. Strip the sheath over the minimum length, arrange the conductors according to the T568B scheme (or T568A, identical at both ends of the link), trim them flush, insert them fully and crimp with a ratchet crimping tool. After crimping, check the link with a tester.

Can the LAN-6EFTP-PT-LSZH-хх cable be terminated in outlets and patch panels?

Do not terminate stranded cable in the insulation displacement contact (IDC) blocks of outlets and patch panels: these contacts are designed for solid conductors, and thin strands break off. Use a cable with solid conductors for permanent links and use the flexible cable for patch cords.

How do I install the LAN-6EFTP-PT-LSZH-хх cable correctly?

Unwind the cable without loops or kinks and do not exceed the permitted pulling force. Observe the minimum bend radius and do not tighten cable ties so that the sheath is crushed. Do not run the cable close to and in parallel with power lines; cross them at an angle close to 90°. Leave a service loop at the outlet and in the cabinet.

How do I unwind the LAN-6EFTP-PT-LSZH-хх cable from its package and how do I store it?

Pull the cable from the centre of the box without forming loops or figure-eights and hold the box in place. Store the cable in a dry room in its factory packaging and protect the cable ends from moisture and contamination.

Didn’t find an answer to your question?

Product Codes (1)

  • LANMASTER, F/UTP, Category 6, RJ45 patch cord, 4-pair, LSZH, gray, 305 m
Specifications are subject to change without notice. For the most current information, consult LANMASTER or an authorized LANMASTER partner/distributor.